Proreact® Programmable Temperature Linear Heat Detection
Your Challenge:
Monitoring temperature fluctuations in complex environments
In environments with fluctuating ambient temperatures, standard heat detectors can trigger false alarms or fail to detect genuine threats. You need a system that can distinguish between normal operational changes and a real fire risk. The Proreact Programmable linear heat detector provides a reliable solution by compensating for ambient temperature shifts, ensuring accuracy.
- Features & Benefits
- Product Codes
- Resources
-
Programmable Pre-Alarm and Alarm
Set a pre-alarm temperature for early investigation and a higher alarm point for confirmed threats, allowing for a managed response -
Rate-of-Rise Detection
The system triggers an alarm if a rapid temperature increase is detected, providing an early warning for fast-developing fires -
Up to 500m of Detection Per Unit
A single control unit can monitor up to 500 metres of LHD cable, offering cost-effective coverage for large or long areas -
Automatic Temperature Compensation
The system intelligently adjusts to ambient temperature changes, maintaining the accuracy of the alarm activation point and preventing false alarms
-
Manage Risks Proactively
The pre-alarm functionality gives you valuable time to investigate potential hazards before a full alarm is triggered, preventing costly incidents -
Reduce False Alarms
By compensating for normal temperature fluctuations, the detector significantly reduces the risk of false alarms and unnecessary downtime -
Pinpoint Accuracy
Cable-based sensing allows detection to be placed at the precise point of risk, ensuring threats are detected exactly where they occur -
Lower Total Cost of Ownership
With low installation and maintenance costs, combined with high reliability, the system offers a cost-effective long-term safety solution
| Nylon | Stainless Steel | Activation Temperature | Approvals |
| F3051 | F3052 | 54°C (129°F) to 100°C (212°F) | UL, EN54, CNBOP, EN54, RoHS |
| Part No. | Description | Compatibility |
| A1389 | Control Unit | Programmable Activation Temperature |
| A1470 | End of Line Unit | Programmable Activation Temperature |
| A1471 | Junction Box | Programmable Activation Temperature |
| A1149-100 | Ceiling / Wall J-Clip [SS] | Generic |
| A1362-100 | Surface P-Clip [Al] | Generic |
| A1329-100 | Surface P-Clip [SS] | Generic |
| A1174-100 | Cable Tray V-Clip [SS] | Generic |
| A1175-100 | Indoor / Outdoor Tiewrap | Generic |
| A1176-11 | Indoor Tiewrap (High Temp) | Generic |
| A1177-100 | Indoor / Outdoor Tiewrap (High Temp) | Generic |
| C1283-100 | Silicone Sleeves | Generic |
Programmable Linear Heat Detections Ambient Temperature Compensation feature maintains alarm temperature accuracy when there are ambient temperature fluctuations.
As the Temperature (yellow) increases the Cable Resistance drops (green) towards the Alarm Threshold (red, dotted). The system recognises that the whole temperature cable is changing and the Ambient Temperature Compensation feature dynamically reduces the Alarm Threshold (red) to account for this change.
From the graph, with ambient temperature increases, there are several points where the alarm would normally be triggered but these false alarms are avoided ensuring that no unnecessary evacuations take place. Alarm point detection is independent of Ambient Temperature Compensation so, in the event of a fire, the alarm will still be triggered.
Technical Details:
System Control
The Proreact Programmable Composite Control Unit continuously monitors the resistance of the connected sensor cable. It can be configured for a specific pre-alarm and alarm temperature and features a rate-of-rise detection setting. It is compatible with both conventional and addressable fire alarm panels.
Sensor Cable
The Proreact Programmable LHD cable is the sensing element of the system. Its heat-sensitive polymers react to changes in temperature along its entire length. It is available with different protective coatings to suit various industrial and commercial environments.
Environmental
Designed for use in a wide range of indoor and outdoor applications, the system is unaffected by dirt, dust, and damp conditions. The robust design ensures reliable performance in harsh environments, from power stations to cold storage facilities.
Your Questions, Answered
Find the answers to the most common questions about our Proreact Programmable linear heat detector.
What makes a programmable linear heat detector different?
How does the system prevent false alarms from ambient temperature changes?
What is 'rate-of-rise' detection?
Can this heat detector be integrated with an addressable fire panel?
What are the ideal applications for this type of heat detector?
Become an Expert in FFE's
Specialist Fire Detection Solutions
Our FFE Academy offers comprehensive training on all our products.
Enhance your knowledge and skills with our expert-led courses.
Proreact PAT Composite Control Unit Datasheet (EN)
Proreact Pocket Guide (EN)
Live sessions on specialist detection, installation, standards and best practices
Trusted by Professionals
"The Fireray One has been a game-changer for us. The installation was incredibly straightforward, and the reliability is second to none."
Installation Engineer
"We've seen a significant reduction in false alarms since switching to the Fireray One. It's a product I trust and recommend to my clients."
Consultant
"The low maintenance requirements of the Fireray One have saved us considerable time and money."
Facility Manager
"FFE's technical support for the Fireray One has been excellent. They are always on hand to answer our questions."
Partner/System Integrator
"The Fireray One is a reliable and cost-effective solution that we are happy to stock and recommend to our customers."
Distributor
Latest News and Insights
Stay up-to-date with the latest news, articles, and case studies from FFE.
Ready to Simplify Your
Heat Detection Installations?
Contact our team of experts to discuss how the Proreact Programmable linear heat detector can provide a flexible and reliable solution for your project.